Suzuki Grandee of Wetar + General information + Maintenance and greasing + Heater, ventilation and conditioner + Steering + Suspension bracket + Wheels and tires + Forward driving shaft/bearing of a shaft. Oil epiploon + Driveshafts + Brake system + Engines + Fuel system + ignition System + start System + release System + Transmissions + Coupling + Transfer + Forward and back differentials + Windows, mirrors, locks and security measures. Immobilizer - Electric equipment + body Electric equipment + lighting System - Electric equipment system + General description + Diagnostics + the Works made on the car - Major maintenance - Generator Removal Installation Dismantling [Type 60 A] Dismantling [Type 70 A and 80 A] Survey [Type 60 A] Survey [Type 70 A and 80 A] Replacement of brushes Assembly [Type 60 A] Assembly [Type 70 A and 80 A] + Specifications Inhaling moments + Tools/information for drivers
|
Survey [Type 60 A]
Rotor
|
- Using an ohmmeter, check electroconductivity between contact rings of a rotor. If there is no electroconductivity, replace a rotor. Standard resistance: 2.5-2.9.
- Using an ohmmeter, check, whether there is no electroconductivity between a contact ring and the rotor core. If there is an electroconductivity, replace a rotor.
- Check contact rings, whether there is no roughness or a deposit. If they rough or are a deposit, replace a rotor.
|
|
Stator
|
- Using an ohmmeter, check electroconductivity of all contacts. If there is no electroconductivity, replace a stator.
- Using an ohmmeter, whether check there is no electroconductivity between contacts of the coil and the stator core. If there is no electroconductivity, replace a stator.
|
1 — a stator 2 — stator contact |
|
|
Brush and shchetkoderzhatel
|
- Check each brush on wear, having measured its length.
|
- If the brush is worn-out to a limit, replace a brush.
- Length of a brush of "a"
- standard: 16 mm (0.63 inches)
- limit: 2 mm (0.08 inches)
|
|
|
Rectifier
|
- Using an ohmmeter, check electroconductivity between cases of the top and bottom rectifiers and contact of each diode.
- Check both directions, having changed щупы an ohmmeter. In each case there should be only unilateral conductivity. If result of check unsatisfactory, replace the rectifier.
|
- Check unilateral electroconductivity between contacts and three diodes similarly described in item 1.
|
|
1 — the rectifier 2 — diode contact |
|
|
Condenser
Check condenser capacity. Condenser capacity: 0.5 µF.
|