Table A. Check of a chain of an alarm lamp of ABS
The lamp is not lit at ignition switch inclusion
Chain description
(Inclusion/switching off) of an alarm lamp of ABS operates work the module of management of ABS via the module of a drive of a lamp of ABS in the combined counter.
If the anti-blocking brake system in a good condition, the module of management of ABS includes an alarm lamp of ABS at ignition switch inclusion, 2 seconds let's to a lamp burn only and disconnects it. If in system malfunction is found, the module of management of ABS includes a lamp. The lamp also joins the ABS driver module in the combined counter when the socket of the module of management of ABS is disconnected.
Survey
Model with folding top
Step
|
Action
|
Yes
|
No
|
1
|
Include an ignition switch. Whether other alarm lamps light up?
|
Pass to a step 2
|
Pass to a step 4
|
2
|
Disconnect an ignition switch
Disconnect the socket of the hydraulic block/module of management of ABS
Include an ignition switch. Whether the alarm lamp of ABS is lit at ignition switch inclusion?
|
Replace assembly of the hydraulic block/module of management of ABS
|
Pass to a step 3
|
3
|
Remove the combined counter at the disconnected ignition switch. Whether in a good condition ABS lamp?
|
The chain of "BLU/ORN" is short-circuited on the earth. If OK, replace a chain of an alarm lamp of ABS (the module of the driver of a lamp)
|
Replace a lamp
|
4
|
Whether in a good condition IG safety lock?
|
"BLK/WHT" wire to the combined counter or bad connection is opened
|
Repair and replace
|
Besides model with folding top
Step
|
Action
|
Yes
|
No
|
1
|
Include an ignition switch. Whether other alarm lamps light up?
|
Pass to a step 2
|
Pass to a step 4
|
2
|
Disconnect an ignition switch
Disconnect the socket of the hydraulic block/module of management of ABS
Include an ignition switch. Whether the alarm lamp of ABS is lit at ignition switch inclusion?
|
Replace assembly of the hydraulic block/module of management of ABS
|
Pass to a step 3
|
3
|
Remove the combined counter at the switched-off ignition switch
Measure resistance between "BLU/ORN" wire from the 22-vyvodny socket of the combined counter and the earth. Whether it is infinite ()?
|
Pass to a step 6
|
The chain of "BLU/ORN" is short-circuited on the earth
|
4
|
Whether in a good condition a safety lock "COUNTER"?
|
Pass to a step 5
|
Replace a safety lock and check, whether there is no short circuit of a chain on the earth
|
5
|
Remove the combined counter at the switched-off ignition switch.
Check contact between a wire of "BLK/WHT" and the 20-vyvodny socket combined the counter
If OK, include an ignition switch and measure tension at a wire of "BLK/WHT" of the 20-vyvodny socket of the combined counter. Whether it is equal 10-14 In?
|
Pass to a step 6
|
"BLK/WHT" chain is opened
|
6
|
Measure resistance between a wire of "BLK" of the 20-vyvodny socket of the combined counter and the earth. Resistance is lower 5?
|
Replace the combined counter
|
"BLK" a chain is opened or high resistance
|
Table B. Check of a chain of an alarm lamp of ABS
The lamp constantly burns
See the scheme of a chain of system and the chain description in the Table A.
Survey
Step
|
Action
|
Yes
|
No
|
1
|
Execute check of codes of diagnostics of malfunctions. Whether there is any KDN (including a code 12, there are no CODES/NO CODES on the SUZUKI scanner)?
|
Pass to a step 2
|
Pass to a step 3
|
2
|
Whether there is a code of malfunction of KDN (besides a code 12) in a step 1?
|
Pass to a step 7 Sections the Table of diagnostics of malfunctions of ABS in this Chapter
|
Pass to a step 3
|
3
|
Whether in a good condition "IG" safety lock (model with folding top) or ABS safety lock (besides model with folding top)?
|
Pass to a step 4
|
Replace a safety lock and check, whether there is no short circuit of a chain
|
4
|
Disconnect an ignition switch.
Disconnect the socket of the hydraulic block/module of management of ABS the socket (1).
Check contact of the socket of the hydraulic block/module of management of ABS at conclusions of "A17", "A25" and "A10".
If OK, include an ignition switch and measure tension at a conclusion of "A25" of the socket. Whether it is equal 10-14 In?
|
Pass to a step 5
|
"BLK/WHT" chain (model with folding top) or "GRN/ORN" chain (besides model with folding top) is opened.
|
5
|
At the disconnected socket of the module of management of ABS, include an ignition switch and light an alarm lamp of ABS.
Connect a conclusion of "A17" of the disconnected socket to the earth using an office wire. Whether the alarm lamp of ABS dies away?
|
Pass to a step 6
|
"BLU/ORN" chain is opened. If a wire and contact as it should be, replace the module of the driver of a lamp of ABS (model with folding top) or the combined counter (besides model with folding top).
|
6
|
Measure resistance from an A10 socket conclusion with the earth. Resistance is lower 5?
|
Replace with the serviceable hydraulic block/module of management of ABS and again check
|
"BLK" a chain is opened or high resistance
|
Table C. Check of a chain of an alarm lamp of ABS
The lamp constantly blinks at the included ignition switch
Chain description
When the conclusion switch of diagnostics is short-circuited or will close on the earth at the included ignition switch, the code of malfunction (KDN) is displayed by a blinking of an alarm lamp of ABS only in the following cases.
- Normal KDN (12) is displayed, if it is not revealed a code of malfunction of KDN in ABS.
- The history of codes of malfunction of KDN is displayed by a lamp blinking if there is no current code of malfunction though the history of codes of malfunction of KDN is kept in memory.
Survey
Step
|
Action
|
Yes
|
No
|
1
|
Whether the conclusion of a wire of the diagnostic PNK (3) switch is connected to a conclusion of a wire of "BLK" (2) through a service wire (4)?
|
Pass to a step 3
|
Pass to a step 2
|
2
|
Ignition switch INCL.
Measure tension between a conclusion of the diagnostic switch and the earth. Whether it is equal 10-14 In?
|
Replace with the serviceable hydraulic block/module of management of ABS and again check
|
The chain of a wire of "PNK" is short-circuited on the earth
|
3
|
Ignition switch INCL.
Whether points a blinking of an alarm lamp of ABS to KDN?
|
Pass to a step 7 Sections the Table of diagnostics of malfunctions of ABS in this Chapter
|
Replace with the serviceable hydraulic block/module of management of ABS and again check
|
Fig. for a step 1
Model with folding top
|
1 — I will corrode diagnostics |
Besides model with folding top
|
1 — I will corrode diagnostics |
Table D. The code (KDN) is not deduced, even if the conclusion of the switch of diagnostics is connected on the earth
Chain description
When the conclusion of the diagnostic switch is connected on the earth at included an ignition switch, the module of management of ABS deduces a code of diagnostics of malfunction a blinking of an alarm lamp of ABS.
Survey
Step
|
Action
|
Yes
|
No
|
1
|
Whether there is no short circuit of a conclusion of a wire of the diagnostic PNK (3) switch and a conclusion of a wire of "BLK" (2) an office wire (4)?
|
Pass to a step 2
|
Reliably connect an office wire
|
2
|
Disconnect an office wire
Disconnect an ignition switch
Disconnect the socket of the hydraulic block/module of management of ABS (1).
Measure resistance between a conclusion of the diagnostic switch and an A8 socket conclusion. Whether it is infinite ()?
|
"PNK" chain is opened
|
Pass to a step 3
|
3
|
Measure resistance between between a conclusion of grounding of the socket of the monitor and the case. Resistance is lower 5?
|
Pass to a step 4
|
The chain of "BLK" or bad contact is opened
|
4
|
Check contact of the hydraulic block/module of management of ABS at "A8" and "A10" conclusion
If OK, then check a chain of an alarm lamp of ABS, having addressed to Tables of diagnostics of malfunctions - A, B or C in this Section. A chain in a good condition?
|
Replace on serviceable hydraulic block/assembly of the module of management of ABS and again check
|
Repair a chain of an alarm lamp of ABS
|
Fig. for a step 1
Model with folding top
|
1 — I will corrode diagnostics |
Besides model with folding top
|
1 — I will corrode diagnostics |
Table E. Check of an alarm lamp of EBD (an alarm lamp of a brake)
The lamp constantly burns
Chain description
Work of an alarm lamp of EBD (alarm lamp of a brake) the switch of the parking brake, the switch of level of brake liquid and assembly of the module of the management/the ABS hydraulic block via the driver of a drive of a lamp in the combined counter operates. See the chain chart in the Table A.
Survey
Step
|
Action
|
Yes
|
No
|
1
|
Be convinced that:
The parking brake is completely released.
Level of brake liquid is higher than the minimum. Results of check positive?
|
Pass to a step 2
|
Completely release the parking brake and/or fill up level of brake liquid
|
2
|
It is model with folding top?
|
Pass to a step 4
|
Pass to a step 3
|
3
|
Check chain of the indicator of the prevention of a brake
Check a chain of the indicator of the prevention of a brake, having addressed to the Section Warning a signal of a display lamp in Head Tools/information for drivers. A chain in a good condition?
|
Pass to a step 4
|
Repair or replace faulty parts
|
4
|
Whether the alarm lamp of ABS lights up?
|
Execute the actions described in the Table B in this Section
|
Pass to a step 5
|
5
|
Disconnect the socket of the hydraulic block/module of management of ABS at the disconnected ignition switch
Check contact of the socket of the hydraulic block/module of management of ABS at "A26" conclusions
If contact as it should be, substitute boots under wheels and choose neutral transfer (P range for A/t)
Holding the brake lever pressed, include an ignition switch
Release the parking brake
Connect a conclusion of "A26" of the disconnected socket to the earth, using an office wire
Whether the alarm lamp of EBD (an alarm lamp of a brake) is disconnected?
|
Replace on serviceable hydraulic block/assembly of the module of management of ABS and again check
|
"BRN" chain (model with folding top) or "ORN" chain (for other models) is opened
If a wire and contact as it should be, replace the combined counter
|
|