 Suzuki Grandee of Wetar
 + General information
 + Maintenance and greasing
 + Heater, ventilation and conditioner
 + Steering
 + Suspension bracket
 + Wheels and tires
 + Forward driving shaft/bearing of a shaft. Oil epiploon
 + Driveshafts
 + Brake system
 + Engines
 + Fuel system
 + ignition System
 -  Start system
 + General description
 -  Diagnostics
 Block repair
 Analysis
 Assembly
 Survey
 Work check
 Specifications
 Type of 0.9 kV
 Necessary materials
 Special tool
 + release System
 + Transmissions
 + Coupling
 + Transfer
 + Forward and back differentials
 + Windows, mirrors, locks and security measures. Immobilizer
 + Electric equipment
 
 
 
 
 
 | 
 Survey   Piston  
|  | Check the piston on wear. Replace, if it is necessary. |   Electromagnetic switch  
|  | Insert the piston and release. The piston should return to initial situation quickly. Replace it if it is necessary. |   Check of a chain of the involving coil  
|  | Check electroconductivity of conclusions of 'S' and the 'M' electromagnetic switch. If there is no electroconductivity, the coil is opened and it is necessary to replace it. |   Check of a chain of the holding coil  
|  | Check electroconductivity of a conclusion of 'S' of the electromagnetic switch and the coil case. If there is no electroconductivity, the coil is opened and it is necessary to replace it. |   Sleeve of a shaft of an anchor  
|  | Check a sleeve on wear or damages. Replace, if it is necessary. |   Brush  
|  |  
| 
| 
 Check brushes on wear.  
|  | 
 Measure length of a brush and if it is lower than a limit, replace a brush.  |  
 Length of a brush 
 
|  |  Types of 0.9 kV and 1.2 kV  |  Type of 1.4 kV  |  
|  standard  |  12.3 mm (0.44 inches)  |  16.5 mm (0.65 inches)  |  
|  limit  |  7 mm (0.28 inches)  |  
 Establish brushes on a shchetkoderzhatel and check, whether smooth movement.  |  |   Spring  
|  | Check springs of brushes on wear, damage or other malfunctions. Replace, if it is necessary. |  
 Tension of a spring of a brush 
 
|  Standard  |  1.9 — 2.5 kg (3.97 pounds)  |  
|  Limit  |  0.6 kg (1.32 pounds)  |  Shchetkoderzhatel  
|  |  
| 
| 
|  | 
 Check brush movement in a shchetkoderzhatel. If the brush in a shchetkoderzhatel gets stuck, believe, whether the shchetkoderzhatel is bent and whether sliding surfaces are soiled. Clear or correct, if it is necessary.  |  
 Check electroconductivity between a positive conclusion of a brush and the earthed shchetkoderzhatel. If there is an electroconductivity, the shchetkoderzhatel is earthed it is earthed because of defect of isolation and it should be replaced.
 |  |   Anchor  
|  |  
| 
| 
|  | 
 Check a collector, whether there is no dirt and a deposit. Correct by means of an emery paper or the lathe if it is necessary.  |  
 Check, evenly or the collector is worn-out, having fixed an anchor on V-shaped blocks. If the deviation of an arrow of the indicator exceeds a limit, repair or replace.  
|  | The specification assumes below that an anchor will not bend. It is necessary to replace the Pognuty anchor.  |  
 
  Collector not the round 
  Standard: 0.05 mm (0.002 inches) or less  Limit: 0.4 mm (0.015 inches)  
|  | 1 — an anchor 2 — V-block
 3 — a magnetic rack
 4 — the strelochny indicator
 |  
|  | 
 Check a collector on wear. If diameter of less limiting, replace an anchor. 
 External diameter of a collector: 
 standard: 29.4 mm (1.16 inches) limit: 28.8 mm (1.13 inches)  |  
 Check depth of isolation of a collector. Correct or replace, if it less limiting. 
 Depth of isolation of a collector of "a": 
 standard: 0.4-0.6 mm (0.015 - 0.023 inches)  limit: 0.2 mm (0.008 inches)  
| 
 
  | 1 — a collector segment 2 — an insulator
 |  |  |   Grounding check  
|  | Check a collector and the anchor core. If there is an electroconductivity, the anchor is earthed and it is necessary to replace it. |   Chain check  
|  | Check electroconductivity between segments. If there is no electroconductivity in any checked points, the chain is opened, and it is necessary to replace an anchor. |   Transfers  
|  | Check internal and planetary transfers on wear, damage or other malfunctions. Replace, if it is necessary. |   Gear and obgonny coupling  
|  |  
| 
| 
 Check a gear on wear, damage or other damages.  
|  | 
 Check that the coupling is stopped, if it to turn in the drive direction, and smoothly rotates in the opposite direction. Replace, if it is necessary.  |  
 Check a shaft teeth on wear or damage. Replace, if it is necessary.  
|  | 
 Check smoothness of movement of a gear.  |  |  |   Sleeve of a forward casing  
|  | Check a sleeve on wear or damage. Replace, if it is necessary. |  
 | 
 
 
 
      
 
 |